Review Question - QID 5972

In scope icon L 2 E
QID 5972 (Type "5972" in App Search)
Compared to metal-on-polyethylene total hip bearing surfaces, the debris particles generated by metal-on-metal articulations are

larger and less numerous.

6%

76/1284

larger and more numerous.

10%

128/1284

smaller and less numerous.

10%

126/1284

smaller and more numerous.

74%

945/1284

not detectable.

0%

5/1284

Select Answer to see Preferred Response

bookmode logo Review TC In New Tab

Retrieval studies have shown that the debris particles produced by metal-on-metal articulations in total hip arthroplasty are several orders of magnitude smaller and may be up to 100 times more numerous than those found with metal-on-polyethylene articulations.