Review Question - QID 3035

In scope icon L 1 B
QID 3035 (Type "3035" in App Search)
A patient with an intertrochanteric hip fracture undergoes reduction and dynamic hip screw application. The post-operative radiographs demonstrate that the lag screw is superior in the femoral head with a tip-apex distance of 40 millimeters. This patient is at increased risk of what complication?

lag screw cutout

96%

1760/1841

osteonecrosis

1%

21/1841

osteoarthritis

1%

14/1841

peri-prosthetic fracture

1%

18/1841

lag screw breakage

1%

22/1841

Select Answer to see Preferred Response

bookmode logo Review TC In New Tab

Baumgaertner et al in their classic study in 1995 determined that the position of the lag screw in the femoral head influenced the risk of cutout of a dynamic hip screw construct in treatment of intertrochanteric fractures. They had no cutouts if the tip-apex distance on the combined AP and lateral radiographs was less than 25 millimeters. Subsequent studies demonstrated a decreased cutout rate once people were aware of the tip-apex distance importance.

REFERENCES (3)
Authors
Rating
Please Rate Question Quality

4.2

  • star icon star icon star icon
  • star icon star icon star icon
  • star icon star icon star icon
  • star icon star icon star icon
  • star icon star icon star icon

(26)

Attach Treatment Poll
Treatment poll is required to gain more useful feedback from members.
Please enter Question Text
Please enter at least 2 unique options
Please enter at least 2 unique options
Please enter at least 2 unique options