Summary The Locking Hand Nail System from Skeletal Dynamics is an intramedullary fixation system designed for the stabilization of fractures of the metacarpals and proximal phalanges The device provides minimally invasive internal fixation through a headless, cannulated nail that is inserted within the medullary canal to maintain fracture alignment while minimizing soft-tissue disruption The system incorporates distal locking screw options to enhance rotational and axial stability, allowing controlled fixation of extra-articular fracture patterns The Locking Hand Nail System is part of a specialized hand fracture fixation platform and includes multiple nail diameters and lengths, dedicated instrumentation, and compatible locking screws to accommodate variations in hand anatomy and fracture configuration Indications Indications extra-articular fractures of the metacarpals extra-articular fractures of the proximal phalanges transverse fractures of the metacarpals or proximal phalanges short oblique fractures amenable to intramedullary fixation fractures requiring minimally invasive fixation Contraindications active or latent infection insufficient bone stock or compromised bone quality inadequate soft-tissue coverage known hypersensitivity or allergy to implant materials fracture patterns unsuitable for intramedullary fixation Anatomy Phalanx osteology distal phalanx login to view 4 more bullets middle and proximal phalanx login to view 14 more bullets arthrology interphalangeal joint login to view 3 more bullets ligaments collateral ligaments login to view 2 more bullets tendons terminal extensor tendon login to view 1 more bullet FDP login to view 1 more bullet central slip login to view 1 more bullet FDS login to view 1 more bullet blood supply proper digital arteries login to view 1 more bullet nervous system proper digital nerves login to view 1 more bullet Metacarpals osteology concave on palmar surface 1st, 4th, and 5th digits form mobile borders 2nd and 3rd digits form stiffer central pillar login to view 1 more bullet three palmar and four dorsal interossei muscles arise from metacarpal shafts tendons extensor carpi radialis longus/brevis login to view 1 more bullet extensor carpi ulnaris login to view 1 more bullet abductor pollicis longus login to view 1 more bullet opponens pollicis login to view 1 more bullet opponens digiti minimi login to view 1 more bullet Approach Metacarpal nails can be introduced either in an antegrade or retrograde direction the illustrated surgical technique uses an antegrade approach fully flex the metacarpophalangeal joint and mark the dorsal third of the metacarpal head open the 3rd extensor compartment for k-wire insertion into the metacarpal head Phalanx fully flex the metacarpophalangeal joint mark the dorsal third of the metacarpal head expose the base of the proximal phalanx by subluxing to allow percutaneous access to the proximal articular surface the illustrated surgical technique uses an antegrade approach, described as less traumatic to the PIP joint retrograde approach is still possible Technique Optional removal flex the hand and create an incision to remove the locking compression screws use a k-wire to find the pocket of the locking nail ream over the k-wire to create a canal for nail removal use sequential reaming as necessary to create the canal engage the drill guide locking screw and remove the nail Metacarpal Technique Primary Steps step 1 insert a 1.6mm k-wire into the metacarpal head and advance it to the fracture site login to view 2 more bullets for the antegrade approach, flex the wrist while advancing the k-wire through the base of the metacarpal until visible login to view 2 more bullets step 2 start reaming with the 2.7mm starter reamer login to view 3 more bullets step 3 assemble the drill guide by inserting the metacarpal drill guide locking screw first, aligning the drill guide tabs with the cutouts on the nail, and fully tightening place the k-wire tip into the cupped front end of the nail and advance the nail into the medullary canal while allowing the k-wire to exit confirm fracture reduction and final nail position with fluoroscopy, ensuring the locking screw holes are not near fracture lines retighten the drill guide locking screw after nail insertion step 4 insert a 1.4mm k-wire through the drill guide hole that is 5mm greater than the chosen nail length for distal provisional fixation insert a 1.4mm k-wire through the most proximal drill guide hole for proximal provisional fixation step 5 make a small incision to prepare for drilling and screw insertion, and bluntly spread the soft tissues with skin hooks login to view 1 more bullet step 6 advance the 2.0mm stop drill through the selected proximal slot, drilling through the near cortex until the mechanical stop reaches the drill guide measure screw length with the 1.4mm drill, stopping before the far cortex insert the selected 1.8mm locking compression screw unicortically step 7 confirm final reduction and implant position using fluoroscopy step 8 repeat the drilling, sizing, screw insertion, and fluoroscopic confirmation steps for the distal screw, taking note of the chosen hand nail length and the drill guide etched sizes step 9 disengage the drill guide locking screw with the cruciform driver and remove the drill guide assembly Phalanx Technique Primary Steps step 1 insert a 1.6mm k-wire into the subluxed proximal phalanx base in line with the medullary canal of the proximal fragment advance the k-wire to the fracture site under fluoroscopy, reduce the fracture, and advance the k-wire into the proximal phalanx head determine nail length with a measurement ruler or depth gauge and subtract 10mm from the length reading login to view 1 more bullet step 2 start reaming with the 2.7mm starter reamer and then sequentially ream with the 3.0mm reamer login to view 3 more bullets step 3 assemble the drill guide by inserting the phalanx drill guide locking screw first, aligning the drill guide tabs with the cutouts on the nail, and fully tightening place the k-wire tip into the cupped front end of the nail and advance the nail into the medullary canal while allowing the k-wire to exit login to view 2 more bullets step 4 fully flex the joints to align the distal phalanx fragment into the correct rotational alignment login to view 2 more bullets step 5 make a small incision to prepare for drilling and screw insertion, and bluntly spread the soft tissues with skin hooks login to view 1 more bullet step 6 advance the 2.0mm stop drill through the selected proximal slot, drilling through the near cortex until the mechanical stop reaches the drill guide login to view 1 more bullet insert the selected 1.8mm locking compression screw unicortically step 7 repeat the distal screw sequence, taking note of the chosen hand nail length and the drill guide etched sizes step 8 confirm final reduction and implant position using fluoroscopy step 9 disengage the drill guide locking screw with the cruciform driver and remove the drill guide assembly Phalanx distal transfixion screw option step 1 attach the phalanx coronal transfixion screw guide to the phalanx drill guide assembly with the provided screws ensure correct rotational alignment by fully flexing all digits simultaneously step 2 under fluoroscopy, advance a 1.1mm k-wire into the guide hole corresponding to the locking hand nail length pass the 1.1mm k-wire from the near cortex, through the nail’s horizontal transfixion hole, and out the far cortex advance the k-wire until it is past the far cortex, then pull from the other side of the digit while leaving the tip where the transfixion screw tip is to be placed in bone step 3 make a small incision around the k-wire and use both skin hooks so the surrounding bone surface is clearly visible for screw insertion use the depth gauge to determine transfixion screw length from the laser etched band on the k-wire remove the depth gauge while leaving the k-wire in place step 4 select the appropriate length gold transfixion screw engage the screw end cup onto the tip of the k-wire and insert the screw while simultaneously pushing or pulling out the k-wire through the other side of the digit tighten the transfixion screw until the head seats fully step 5 remove the transfixion screw guide remove the drill guide assembly, repair soft tissues, and close Technical specifications Metacarpal nail titanium nail diameters 3.0mm 3.5mm 4.0mm available lengths 40mm 45mm 50mm 55mm 60mm 65mm 70mm Phalanx nail titanium nail diameter 3.0mm listed lengths 22.5mm 25mm 27.5mm 30mm 32.5mm 35mm 37.5mm 40mm 42.5mm 45mm 47.5mm 50mm the source describes phalanx nails as available in 1 diameter a lateral or horizontal transfixion screw option is available for phalanx head fractures Instrumentation cannulated manual reamers 2.7mm x 165mm 3.0mm x 165mm 3.5mm x 165mm 4.0mm x 165 mm the phalanx technique specifically uses the 2.7mm and 3.0mm reamers the standard tray includes a measurement ruler, intramedullary nail depth gauge, cannulated awl, wire pusher, metacarpal and phalanx drill guides, 2.0mm stop drill, 1.4mm drill, phalanx Transfixion screw guide, and countersink depth gauge Screws Locking compression screw the locking compression screw is intended to be unicortical the locking compression screw is designed to suck the nail up to the indostial surface of the metacarpal or bone material is CoCr screw diameter is 1.8mm available lengths 4.0mm 5.0mm 6.0mm 7.0mm 8.0mm 9.0mm 10.0mm 11.0mm 12.0mm Phalanx coronal transfixion screw material is CoCr screw diameter is 1.5mm available lengths 6.0mm 7.0mm 8.0mm 9.0mm 10.0mm 11.0mm 12.0mm 14.0mm 16.0mm 18.0mm Pearls & Pitfalls Pearls use fluoroscopy for fracture reduction, length determination, provisional fixation confirmation, screw placement confirmation, and final implant confirmation keep the k-wire in place during reaming and use the wire pusher if necessary flex the metacarpophalangeal joint during insertion point localization and during provisional fixation steps tap drilling is recommended during provisional k-wire fixation retighten the drill guide locking screw after nail insertion to ensure loosening did not occur ensure the locking screw holes are not placed near fracture lines subtract 10mm from ruler or depth gauge length measurements in the phalanx transfixion screw technique, fully flex all digits simultaneously to assess rotational alignment the supplied 1.1mm k-wires provide exact depth readings with the system’s depth gauge Pitfalls do not use the awl under power do not ream under power use caution and an oscillatory hand motion during awl insertion and reaming to protect nearby soft tissue and tendons do not advance the metacarpal awl beyond its stop, which is 10mm or less from subchondral bone carefully identify and protect the extensor tendons during screw insertion do not ream larger than 3.0mm in the phalanx