BACKGROUND:
We sought to assess if the medullary diameter to cortical width ratio (MD:CW), canal flair index (CFI), and canal fill (CF) of the proximal radius were associated with the presence of stress shielding (SS) after a MoPyC radial head arthroplasty.

MATERIALS AND METHODS:
We conducted a retrospective, international, multicenter (4 centers) study. A total of 100 radial head arthroplasties in 64 women and 36 men with a mean age of 58.40 years ± 14.90 (range, 25.00-91.00) were included. Radiographic measurements, including MD:CW, CFI, CF, and postoperative SS were captured at a mean follow-up of 3.9 years ± 2.8 (range, 0.5-11).

RESULTS:
SS was identified in 60 patients. Mean preoperative MD:CW, CFI, and CF were 0.55 ± 0.09, 1.05 ± 0.18, and 0.79 ± 0.11, respectively. The presence of SS was significantly associated with MD:CW (adjusted odds ratio = 13.66; P = .001), and expansion of the stem (adjusted odds ratio = 3.78; P = .001). The amount of the SS was significantly correlated with expansion of the stem (aβ 4.58; P <  .001).

CONCLUSIONS:
Our study found that MD:CW was an independent risk factor of SS after MoPyc radial head arthroplasty. Autoexpansion of the MoPyc stem significantly increased the risk of SS and its extent. Further studies involving multiple implants designs are needed to confirm the preliminary observations presented in the current study.