• PURPOSE
    • Bipolar hemiarthroplasty has been shown to have a lower rate of dislocation than total hip arthroplasty. However, as the influencing risk factors for bipolar hemiarthroplasty dislocation remain unclear, we aimed to analyse patient and surgeon-specific influencing risk factors for bipolar hemiarthroplasty dislocation.
  • METHODS
    • We retrospectively analysed patients who were operated between 2012 and 2018 and had dislocated bipolar hemiarthroplasty and matched them to patients without a dislocated bipolar hemiarthroplasty, operated between 2018 and 2019. The study was limited to patients who received either a pre- or postoperative pelvic computed tomography. Besides demographic, morphologic, and physiologic data, we analysed duration of surgery; ASA score; Charlson Comorbidity Index; Almelo Hip Fracture Score; Parker Score; and acetabular morphology angles including acetabular anteversion angle, posterior acetabular sector angle, posterior wall angle, and acetabular roofing.
  • RESULTS
    • We included nine patients with a dislocated bipolar hemiarthroplasty and 30 with a non-dislocated bipolar hemiarthroplasty. Patient-specific factors prompting a higher risk for dislocated bipolar hemiarthroplasty were longer duration of surgery (min) (115 ± 50 vs. 80 ± 27, p = 0.01); dementia (56% vs. 13%, p < 0.01); smaller posterior acetabular sector angle (°) (96 ± 6 vs. 109 ± 10, p < 0.01); and smaller posterior wall angle (°) (67 ± 6 vs. 77 ± 10, p = 0.02).
  • CONCLUSION
    • Dementia and insufficient posterior wall angle were associated with higher risk of dislocation in bipolar hemiarthroplasty.