• BACKGROUND
    • Here, we compared the clinical and radiographic outcomes between coracoclavicular (CC) fixation with Mersilene tape and hook plate for acute unstable acromioclavicular (AC) joint dislocation treatment.
  • METHODS
    • We enrolled 49 patients with unstable acute AC dislocation who, between January 2010 and January 2014, underwent surgery with single CC suture fixation with Mersilene tape (M group, 25 cases) or clavicle hook plate (H group, 24 cases). In M and H groups, the average age was 43.7 (range 18-72) and 42.0 (range 17-84) years, the male to female ratio of each group was 15:20 and 19:5, and the injured side left to right ratio was 12:13 and 11:13, respectively. All patients were right-handed. We retrospectively compared the operation time, complication rate, visual analog scale (VAS), University of California at Los Angeles (UCLA) shoulder rating scale, Oxford shoulder scores, and the radiographic outcomes based on reduction loss of CC distance on postoperative follow-up.
  • RESULTS
    • No significant difference in patient demographics between the two groups in age (p = 0.709), gender (p = 0.217), time from injury to surgery (p = 0.863), and injured side (p = 1.000). The mean follow-up was 26.2 months (range 24-35 months). Nine cases of reduction loss (36%) and one of distal clavicle osteolysis (4%) were noted in the M group. CC distance improvement in the H group was significantly superior to that in the M group at 3 months (before hook plate removal, p < 0.001) and 12 months postoperatively (after hook plate removal, p = 0.004), while subacromial erosions were revealed in nine cases (37.5%) in the H group. No significant difference in operative time (p = 0.846), complication rate (p = 1.000), VAS (p = 0.199), mean UCLA shoulder rating scale (p = 0.353), and Oxford shoulder (p = 0.224) scores between the two groups.
  • CONCLUSIONS
    • Both hook plate and Mersilene tape fixations provided temporary stabilization of acute type V AC dislocation and yielded comparable clinical outcomes. The hook plate provided better maintenance of reduction of radiographic outcomes. CC suture fixation with Mersilene tape may serve as an alternative method of stabilization which provides acceptable outcome without the need of implant removal.