• INTRODUCTION
    • Distal tibial fractures are the most common long bone fractures. Several studies focusing on the methods of treatment of displaced distal tibial fractures have been published. To date, locked plates, intramedullary nails and external fixation are the three most used techniques. The aim of our study was to compare intramedullary nail (IMN) and locked plate (LP) for treatment of this kind of fracture.
  • MATERIALS AND METHODS
    • We collected data on 81 patients with distal tibial fractures (distance from the joint between 40 and 100 mm) and we divided into two groups: IMN and LP. We compared in the 2 groups the mean operation time, the mean union time, the infection rate the rate of malunion and nonunion, the full weight bearing time.
  • RESULTS
    • No patient in the two groups developed a nonunion. None of the patients obtained a fair or poor outcome. Overall 52 patients obtained an excellent result (69.3%) and 23 obtained a good result (30.6%).
  • DISCUSSION
    • Our study results indicate a superiority of IMN over LP in terms of lower rates of infections and statistically significant shorter time to full weight bearing. Whereas LP appeared to be advantageous over IMN in terms of leading to a better anatomical and fixed reductions of the fracture and a lower rate of union complications. The two treatments achieved comparable results in terms of operation time, hospital stay, union time and functional outcomes.