• INTRODUCTION
    • Surgical fixation is the standard management of the subtrochanteric fractures. Proximal femoral locked plating (PF-LCP) provides a strong construct for fixation with a high success rate. However, some studies reported implant failure due to loss of the postero-medial bone support and recommended an anatomical reduction. Other studies reported excellent to good results with indirect (biological) fixation without anatomical reduction. In this study, we reviewed the short-term clinical results of PF-LCP fixation for subtrochanteric fractures using both conventional and biological fixation.
  • MATERIALS AND METHODS
    • Forty six patients (34 males and 12 females) with comminuted subtrochanteric fractures were included aged between 18 and 74 (mean 44.3 years). They were treated in a single-blind random manner by either conventional (open, direct) or biological (indirect) reduction method and internal fixation with PF-LCP. Intra-operative variables including; duration of surgery, blood loss, fluoroscopy time and any complications were recorded. Post-operative differences including; duration of healing, implant failure, complications and the final clinical outcome by Harris Hip Score (HHS) were documented.
  • RESULTS
    • 44 cases continued to the final follow-up (23 of the open fixation group and 21 of the biological fixation group). Patients of open group demonstrated greater blood loss (756±151 vs. 260±39ml; P<0.0001), longer operative times (129±16.9 vs. 91±8min; P<0.0001) and incisions (s) length (20.4±3 vs. 13.4±1cm; P<0.0001). More patients needed blood transfusion in open group (11 patients vs. six in closed group; P<0.0001). Patients of biological group demonstrated longer fluoroscopy time (80.9±7.3 vs. 47.2±5.8sec.; P<0.0001). For each group, one case of implant failure was recorded. Low patient compliance was a detrimental factor for the implant failure in both cases. No much difference was demonstrated for the healing rate (open group; 18.3±3.7 vs. biological group16.5±4 weeks; P<0.058) and for the functional outcome (open group; excellent/good: 54%/37%, biological group; excellent/good: 57%/33%; P=0.766).
  • CONCLUSION
    • PF-LCP provided a strong construct for fixation of the comminuted subtrochanteric fractures either by open or biological techniques. Low patient compliance is an influential factor for implant failure in both types.