• ABSTRACT
    • There are currently few published studies examining the use of locking compression plates for the treatment of periprosthetic femoral fractures. Fifteen total hip or knee arthroplasty patients with 16 Vancouver type B1 and C fractures with an average age of 76 years were fixed and followed clinically and radiographically for 2 years. Fourteen patients achieved radiographic union by 6 months, and 13 patients were ambulatory by 6 months. There were no intraoperative complications. In summary, locking plates offer a viable treatment option for these difficult fractures. We advocate a minimum of 10 cortices of fixation (with unicortical or bicortical screws and cable combinations) above and below the fracture. Bone grafting should be used if the soft tissue envelope is violated with extensive dissection, and cortical struts should be considered in cases of failed hardware and revision fixation.