• OBJECTIVE
    • To report the results from functional bracing of isolated ulnar shaft fractures.
  • DESIGN
    • Retrospective review.
  • SETTING
    • Two university hospitals.
  • PATIENTS
    • Isolated ulnar shaft fractures in 444 patients were stabilized in functional braces that permitted full range of motion of all joints.
  • INTERVENTION
    • Prefabricated braces that extended from below the elbow to above the wrist were applied within the first week after the initial injury.
  • OUTCOME MEASURES
    • Union of the fracture, fracture angulation, and final range of motion of the forearm were evaluated.
  • RESULTS
    • Two hundred eighty-seven patients were available for follow-up (65 percent). Union took place in 99 percent of the fractures. Shortening of the ulna averaged 1.1 millimeters (range 0 to 10 millimeters). Final radial angulation averaged 5 degrees (range 0 to 18 degrees). Dorsal angulation averaged 5 degrees (range 0 to 20 degrees). Average loss of pronation was greatest in fractures of the proximal third of the ulna, averaging 12 degrees. Fractures in the distal third averaged a loss of 5 degrees of pronation.
  • CONCLUSIONS
    • Functional bracing is a viable therapeutic alternative in the management of isolated ulnar shaft fractures. It is associated with a 99 percent union rate and good to excellent functional results in more than 96 percent of patients.