• BACKGROUND
    • The rate of operative fixation of acute midshaft clavicle fractures has exponentially increased in recent years; however, the rate of reoperation for symptomatic hardware removal remains high and the optimal fixation strategy unknown. This systematic review aimed to summarize available evidence for dual plating of acute displaced midshaft clavicle fractures.
  • METHODS
    • EMBASE, MEDLINE, and PubMed searches identified clinical studies evaluating dual plate fixation of acute midshaft clavicle fractures. Pooled analysis was performed using a random-effects model in RevMan 5.3.
  • RESULTS
    • Eleven studies including 672 patients were included. Hardware removal occurred in 4.4% and 12.3% of patients undergoing dual and single plate fixation, respectively. Compared to single plating, dual plating had significantly lower odds of hardware removal (P = 0.001) with no difference in union rates. There were no significant differences in reoperation (excluding hardware removal), complications, and patient-reported outcomes between the two groups (P > 0.05).
  • CONCLUSIONS
    • This study suggests that dual plating of acute displaced midshaft clavicle fractures may lead to lower rates of reoperation for symptomatic hardware removal without compromising fracture healing. Ultimately, well-designed randomized trials are needed to further investigate the findings from this systematic review.