• BACKGROUND
    • Leg length discrepancy after total hip arthroplasty is a frequent complication. The aim of this study was to assess the validity (correlation) and reproducibility (inter-rater agreement) of various intraoperative hip radiographs measures to estimate leg length.
  • METHODS
    • Patients were included if they were aged 15 years or older; were eligible for a total hip arthroplasty, and were operated in lateral recumbent. An intraoperative hip radiograph was performed with the definitive implants in place. At 6 weeks postoperatively, anteroposterior pelvis radiograph was taken. We used 3 measures to assess leg length: the height from the ischial tuberosity to the lesser trochanter (LTI), the height from the center of femoral head to the greater trochanter (GTC), and to the inferior teardrop (TC).
  • RESULTS
    • The study group consisted of 71 hips with an average age of 69 years (range, 24-92 years). The correlation was 0.545 (95% CI: 0.35-0.69) for GTC, 0.75 (95% CI: 0.61-0.84) for TC, and 0.70 (95% CI: 0.56-0.80) for LTI. Intraoperative and postoperative measures were statistically different for GTC (<0.0001) and TC (<0.0001), and not significant for LTI (P = .06). Reproducibility of these measures were excellent with intraclass correlation coefficients of 0.977, 0.814, and 0.983 for the GTC, TC, and LTI, respectively.
  • CONCLUSION
    • None of the parameters used to assess leg-length based on an intraoperative radiograph showed good correlation with the postoperative radiograph.